Earthquakes and Structures
Volume 23, Number 2, 2022, pages 197-206
DOI: 10.12989/eas.2022.23.2.197
Evaluation of ductility capacity of steel-timber hybrid buildings for seismic design in Taiwan
Pei-Ching Chen and I-Ping Su
Abstract
Recently, steel-timber hybrid buildings have become prevalent worldwide because several advantages of both steel
and timber structures are maintained in the hybrid system. In Taiwan, seismic design specification related to steel-timber hybrid
buildings remains void. In this study, the ductility capacity of steel-timber hybrid buildings in Taiwanese seismic design
specification is first proposed and evaluated using nonlinear incremental dynamic analysis (IDA). Three non-linear structural
models, 12-story, 8-story, and 6-story steel-timer hybrid buildings were constructed using OpenSees. In each model, Douglas-fir
was adopted to assemble the upper 4 stories as a timber structure while a conventional steel moment-resisting frame was
designated in the lower part of the model. FEMA P-695 methodology was employed to perform IDAs considering 44
earthquakes to assess if the ductility capacity of steel-timber hybrid building is appropriate. The analytical results indicate that
the current ductility capacity of steel moment-resisting frames can be directly applied to steel-timber hybrid buildings if the drift
ratio of each story under the seismic design force for buildings in Taiwan is less than 0.3%. As a result, engineers are able to
design a steel-timber hybrid building straightforwardly by following current design specification. Otherwise, the ductility
capacity of steel-timber hybrid buildings must be modified which depends on further studies in the future.
Key Words
ductility capacity; incremental dynamic analysis steel-timber hybrid building; seismic design
Address
Pei-Ching Chen and I-Ping Su:Department of Civil and Construction Engineering, National Taiwan University of Science and Technology, No.43, Sec.4,
Keelung Rd., Taipei 106335, Taiwan