Computers and Concrete
Volume 18, Number 3, 2016, pages 355-366
DOI: 10.12989/cac.2016.18.3.355
Tests of concrete slabs reinforced with CFRP prestressed prisms
Jiongfeng Liang, Deng Yu, Zeping Yang and Xinjun Chai
Abstract
This paper reports the testing of concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) on the flexural behavior. Four concrete slabs were tested, a reference slab reinforced with steel bars, and three slabs reinforced with CFRP prestressed concrete prisms (PCP). All slabs were made with dimensions of 600mm in width, 2200mm in length and 150 in depth. All concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) exhibited CFRP bar rupture failure mode. It was shown that the application of the CFRP prestressed prisms can limit service load deflections and crack width, the increased level of prestress in the CFRP prestressed prism positively affected the maximum crack width. The deflection of concrete slabs reinforced with CFRP prestressed prisms decreased as prestress in the CFRP prestressed prism increased.
Key Words
test; slabs; CFRP; deflection; crack width
Address
Jiongfeng Liang: State Key Laboratory Breeding Base of Nuclear Resources and Environment, Fundamental Science on
Radioactive Geology and Exploration Technology Laboratory, Nanchang, P.R.China
Zeping Yang and Xinjun Chai: Faculty of Civil&Architecture Engineering, East China Institute of Technology, Nanchang, P.R.China
Deng Yu: College of Civil and Architecture Engineering, Guangxi University of Science and Technology, Liuzhou, P.R.China