Effects of wind barriers on running safety of trains for
urban rail cable-stayed bridge
Wei He,Xiang-Rong Guo,Zhi-hui Zhu,Pengru Deng,Xu-hui He
Abstract
Considering the wind barriers induced aerodynamic characteristic variations of both bridge deck and trains, this
paper studies the effects of wind barriers on the safety and stability of trains as they run through an urban rail transit cable-stayed
bridge which tends to be more vulnerable to wind due to its relatively low stiffness and lightweight. For the bridge equipped
with wind barriers of different characteristics, the aerodynamic coefficients of trains and bridge decks are obtained from wind
tunnel test firstly. And then, the space vibration equations of the wind-train-bridge system are established using the
experimentally obtained aerodynamic coefficients. Through solving the dynamic equations, one can calculate the dynamic
responses both the trains and bridge. The results indicate that setting wind barriers can effectively reduce the dynamic responses
of both the trains and bridge, even though more wind forces acting on the bridge are caused by wind barriers. In addition, for
urban rail transit cable-stayed bridges located in strong wind environment, the wind barriers are recommended to be set with
20% porosity and 2.5 m height according to the calculation results of cases with wind barriers porosity and height varying in two
wide ranges, i.e., 10% - 40% and 2.0 m to 4.0 m, respectively.
Wei He:School of Civil Engineering, Anhui Jianzhu University, Hefei, 230601, China/ National Engineering Laboratory for Structural Health Monitoring and Disaster Prevention, Anhui Jianzhu University, Hefei, 230601, China
Xiang-Rong Guo: School of Civil Engineering, Central South University, Changsha, 410075, China
Zhi-hui Zhu: School of Civil Engineering, Central South University, Changsha, 410075, China
Pengru Deng: Faculty of Engineering, Hokkaido University, Sapporo, 0608628, Japan
Xu-hui He: School of Civil Engineering, Central South University, Changsha, 410075, China