Recently, there has been significant interest in structural health monitoring for civil engineering applications. In this research, a specially designed tendon, proposed by embedding FBG sensors into the center king cable of a 7-wire strand tendon, was applied for long-term health monitoring of tensile forces on a ground anchor. To make temperature independent sensors, the effective temperature compensation of FBG sensors must be considered. The temperature sensitivity coefficient
Key Words
effective temperature compensation; FBG sensors; long-term monitoring; ground anchor tensile force
Address
Department of Civil and Environmental Engineering, Chonnam National University, Yeosu 550-749, Korean