Structural Engineering and Mechanics

Volume 52, Number 3, 2014, pages 541-558

DOI: 10.12989/sem.2014.52.3.541

Seismic rehabilitation of RC frame using epoxy injection technique tested on shaking table

Jiangtao Yu, Yuanmiao Zhang and Zhoudao Lu

Abstract

A 1/4-scale two-bay eight-storey reinforced concrete frame was tested on shaking table. Initial shaking table tests were carried out through a set of real seismic excitations to investigate the seismic behavior of the RC frame. Subsequently, the damaged frame was repaired using epoxy injection technique, and then subjected to the tests with the same records. The purpose of this study was to investigate experimentally the dynamic characteristics, cracking pattern and lateral inter-story stiffness of RC frames using epoxy injection technique. The test results indicate that epoxy-injection technique appears to be a satisfactory method for repairing earthquake-damaged structure.

Key Words

reinforced concrete frame; shaking table test; epoxy injection technique; dynamic characteristic; wedge splitting test

Address

Jiangtao Yu, Yuanmiao Zhang and Zhoudao Lu: Research Institute of Structural Engineering and Disaster Reduction, Tongji University, Shanghai, China