Structural Engineering and Mechanics
Volume 44, Number 6, 2012, pages 775-799
DOI: 10.12989/sem.2012.44.6.775
The structural performance of arches made of few vossoirs with dry-joints
Ernest Bernat-Maso, Lluis Gil and Jordi Marce-Nogue
Abstract
This work approaches the structural performance of masonry arches that have a small ratio between number of vossoirs and span length. The aim of this research is to compare and validate three different methods of analysis (funicular limit analysis F.L.A., kinematic limit analysis K.L.A. and plane stress Finite Element Analysis F.E.A.) with an experimental campaign. 18 failure tests with arches of
different shapes and boundary conditions have been performed. The basic failure mechanism was the formation of enough hinges in the geometry. Nevertheless, in few cases, sliding between vossoirs also played a relevant influence. Moreover, few arches didn\'t reach the collapse. The FLA and KLA didn\'t find a solution close to the experimental values for some of the tests. The low number of vossoirs and joints become a drawback for an agreement between kinematic mechanism, equilibrium of forces and geometry constraints. FLA finds a lower bound whereas KLA finds an upper bound of the ultimate load of the arch. FEA is the most reliable and robust method and it can reproduce most of the mechanism and
ultimate loads. However, special care is required in the definition of boundary conditions for FEA analysis. Scientific justification of the more suitability of numerical methods in front of classic methods at calculating arches with a few vossoirs is the main original contribution of the paper.
Key Words
dry-joint arches; collapsing mechanism; experimental testing; FEA simulation; funicular analysis; kinematic analysis
Address
Ernest Bernat-Maso, Lluis Gil and Jordi Marce-Nogue: Department of Strength of Materials and Engineering Structures, Universitat Politccnica de Catalunya. Barcelona-Tech., ETSEIAT Campus Terrassa, c/Colom, 11, 08222 Terrassa, Spain