Structural Engineering and Mechanics
Volume 14, Number 6, 2002, pages 649-660
DOI: 10.12989/sem.2002.14.6.649
Reinforced concrete beam-column joints with lap splices under cyclic loading
Athanasios I. Karabinis
Abstract
Experimental results are presented from tests conducted on reinforced concrete beam-column joints with lap splices under reversed cyclic loading simulating earthquake action. Response curves are compared for twenty-four specimens designed according to Eurocode 2. The main parameters of the investigation are, the geometry of the reinforcing bar extension, the applied axial load (normalized), the available cover over lap splice region extended as length required from Eurocode 2, as well as the shape and the volumetric percentage of the stirrups confining the lap splice zone. The results are evaluated with regards to the load intensity, the energy absorption capacity and the charateristics of the load deflection curve.
Key Words
reinforced concrete; joints; beam-column connections; lap splices; bond; cyclic load; Euro-code 2.
Address
Department of Civil Engineering, Democritus University of Thrace, Xanthi 67 100, Greece