Steel and Composite Structures
Volume 52, Number 4, 2024, pages 419-434
DOI: 10.12989/scs.2024.52.4.419
Accurate theoretical modeling and code prediction of the punching shear failure capacity of reinforced concrete slabs
Rajai Z. Al-Rousan and Bara'a R. Alnemrawi
Abstract
A flat slab is a structural system where columns directly support it without the presence of beam elements. However,
despite its wide advantages, this structural system undergoes a major deficiency where stresses are concentrated around the
column perimeter, resulting in the progressive collapse of the entire structure as a result of losing the shear transfer mechanisms
at the cracked interface. Predicting the punching shear capacity of RC flat slabs is a challenging problem where the factors
contributing to the overall slab strength vary broadly in their significance and effect extent. This study proposed a new
expression for predicting the slab's capacity in punching shear using a nonuniform concrete tensile stress distribution assumption
to capture, as well as possible, the induced strain effect within a thick RC flat slab. Therefore, the overall punching shear
capacity is composed of three parts: concrete, aggregate interlock, and dowel action contributions. The factor of the shear spanto-depth ratio (a_v⁄d) was introduced in the concrete contribution in addition to the aggregate interlock part using the maximum
aggregate size. Other significant factors were considered, including the concrete type, concrete grade, size factor, and the
flexural reinforcement dowel action. The efficiency of the proposed model was examined using 86 points of published
experimental data from 19 studies and compared with five code standards (ACI318, EC2, MC2010, CSA A23.3, and JSCE).
The obtained results revealed the efficiency and accuracy of the model prediction, where a covariance value of 4.95% was
found, compared to (13.67, 14.05, 15.83, 19.67, and 20.45) % for the (ACI318, CSA A23.3, MC2010, EC2, and JSCE),
respectively.
Key Words
brittle punching; capacity prediction; code provisions; composite slabs; failure mechanism
Address
Rajai Z. Al-Rousan and Bara'a R. Alnemrawi:Department of Civil Engineering, Faculty of Engineering, Jordan University of Science and Technology, P.O. Box 3030, Irbid 22110, Jordan