Steel and Composite Structures

Volume 52, Number 2, 2024, pages 217-236

DOI: 10.12989/scs.2024.52.2.217

Experimental study on hybrid FRP-steel RC shear wall with replaceable dampers

Shiying Xiao and Mengfu Wang

Abstract

The objective of this paper was to discuss the seismic performance of hybrid FRP-steel reinforced concrete shear wall with replaceable friction dampers at the feet of the wall. The hysteretic characteristics of five wall specimens were studied by pseudo-static loading tests. The results showed that the damage of the specimens was concentrated on the friction dampers, and the energy consumption capacity was increased while making up for the defect of low ductility of FRP reinforced wall specimens. And the repairability of the wall after earthquake was improved. Finally, a calculation method of initial stiffness of shear wall with replaceable dampers was proposed.

Key Words

energy consumption capacity; hybrid FRP-steel reinforced concrete shear wall; pseudo-static test; replaceable friction damper; seismic behavior

Address

Shiying Xiao and Mengfu Wang:College of Civil Engineering, Hunan University, Yuelushan, Changsha, Hunan 410082, People's Republic of China