Steel and Composite Structures
Volume 48, Number 1, 2023, pages 27-41
DOI: 10.12989/scs.2023.48.1.027
Elastic local buckling behaviour of corroded cold-formed steel columns
Nie Biao, Xu Shanhua, Hu WeiCheng, Chen HuaPeng, Li AnBang and Zhang ZongXing
Abstract
Under the long-term effect of corrosive environment, many cold-formed steel (CFS) structures have serious
corrosion problems. Corrosion leads to the change of surface morphology and the loss of section thickness, which results in the
change of instability mode and failure mechanism of CFS structure. This paper mainly investigates the elastic local buckling
behavior of corroded CFS columns. The surface morphology scanning test was carried out for eight CFS columns accelerated
corrosion by the outdoor periodic spray test. The thin shell finite element (FE) eigen-buckling analysis was also carried out to
reveal the influence of corrosion surface characteristics, corrosion depth, corrosion location and corrosion area on the elastic
local buckling behaviour of the plates with four simply supported edges. The accuracy of the proposed formulas for calculating
the elastic local buckling stress of the corroded plates and columns was assessed through extensive parameter studies. The
results indicated that for the plates considering corrosion surface characteristics, the maximum deformation area of local
buckling was located at the plates with the minimum average section area. For the plates with localized corrosion, the main
buckling shape of the plates changed from one half-wave to two half-wave with the increase in corrosion area length. The elastic
local buckling stress decreased gradually with the increase in corrosion area width and length. In addition, the elastic local
buckling stress decreased slowly when corrosion area thickness was relatively large, and then tends to accelerate with the
reduction in corrosion area thickness. The distance from the corrosion area to the transverse and longitudinal centerline of the
plate had little effect on the elastic local buckling stress. Finally, the calculation formula of the elastic local buckling stress of the
corroded plates and CFS columns was proposed.
Key Words
cold-formed steel columns, corrosion, elastic local buckling, finite element analysis, surface morphology
Address
Nie Biao, Hu WeiCheng and Chen HuaPeng:School of Transportation Engineering, East China Jiaotong University, Jiangxi, China
Xu Shanhua and Li AnBang: School of Civil Engineering, Xi'an University of Architecture & Technology, Xi'an, China
Zhang ZongXing:Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering,
China University of Mining & Technology, Xuzhou, China