Steel and Composite Structures
Volume 45, Number 4, 2022, pages 605-619
DOI: 10.12989/scs.2022.45.4.605
A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature
Yang You, Liu Le, Jin Xiao, Peijun Wang and Fangzhou Liu
Abstract
The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite
Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was
verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure
modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling
Failure mode (CF). The influence of the flange thickness tb and the temperature exceeded 700°C. The failure modes of T-stubs were mainly decided by the flange thickness,
which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed
by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed
that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.
Key Words
bolted T-stub; design method; failure mode; high temperature; thread-fixed one-side bolt
Address
Yang You:1)School of Transportation and Civil Engineering, Shandong Jiaotong University, 5001 Haitang Road, Changqing District, Jinan,
Shandong Province, People