Steel and Composite Structures
Volume 45, Number 2, 2022, pages 263-279
DOI: 10.12989/scs.2022.45.2.263
Degree of hydration-based thermal stress analysis of large-size CFST incorporating creep
Jinbao Xie, Jianyuan Sun and Zhizhou Bai
Abstract
With the span and arch rib size of concrete-filled steel tube (CFST) arch bridges increase, the hydration heat of
pumped mass concrete inside large-size steel tube causes a significant temperature variation, leading to a risk of thermal stressinduced cracking during construction. In order to tackle this phenomenon, a hydration heat conduction model based on
hydration degree was established through a nonlinear temperature analysis incorporating an exothermic hydration process to
obtain the temperature field of large-size CFST. Subsequently, based on the evolution of elastic modulus based on hydration
degree and early-age creep rectification, the finite element model (FEM) model and analytical study were respectively adopted
to investigate the variation of the thermal stress of CFST during hydration heat release, and reasonable agreement between the
results of two methods is found. Finally, a comparative study of the thermal stress with and without considering early-age creep
was conducted.
Key Words
analytical study; concrete-filled steel tube; early-age creep; hydration heat; temperature; thermal stress
Address
Jinbao Xie:Department of Bridge Engineering, Tongji University, Shanghai 200092, China
Jianyuan Sun and Zhizhou Bai:1)Department of Bridge Engineering, Tongji University, Shanghai 200092, China
2)College of Civil and Architectural Engineering, Xinjiang University, Urumqi 830046, China