Steel and Composite Structures
Volume 45, Number 1, 2022, pages 23-38
DOI: 10.12989/scs.2022.45.1.023
Test and analysis of concrete-filled double steel and double skin tubular columns having outer stainless steel tube
Serkan Tokgoz, Sedat Karaahmetli and Cengiz Dundar
Abstract
This paper presents experimental and analytical studies of eccentrically loaded concrete-filled double steel (CFDST)
and concrete-filled double skin tube (DCFST) columns having outer stainless steel tube. Eighteen CFDST and DCFST column
specimens were manufactured and tested to examine the strength and load-deflection responses. In the study, the main
parameters were concrete strength, load eccentricity, cross section and slenderness. The strengths, load-deflection diagrams and
failure patterns of the columns were observed. In addition, the tested CFDST and DCFST columns were analyzed to attain the
capacity and load versus lateral deflection responses. The obtained theoretical results were compared with the test results. A
parametric study was also performed to research the effects of the ratio of eccentricity (e/Ho) slenderness ratio (L/r), Ho/to ratio,
Hi/ti ratio and the concrete compressive strength on the behavior of columns. In this work, the obtained results indicated that the
ductility and capacity of columns were affected by cross section, concrete strength, steel strength, loading eccentricity and
slenderness.
Key Words
carbon steel tube; concrete-filled steel tube; double skin; double steel; stainless steel tube
Address
Serkan Tokgoz and Sedat Karaahmetli:1Department of Civil Engineering, Adana Alparslan Turkes Science and Technology University, Adana 01250, Turkey
Cengiz Dundar:Department of Civil Engineering, Toros University, Mersin 33340, Turkey