Abstract
An experimental investigation to study the behaviour of connections between cold-formed steel (CFS) joist and
plywood structural panel is presented in this paper. Material testing on CFS and plywood was carried out to assess their
mechanical properties and behaviour. Push-out tests were conducted to determine the slip modulus and failure modes of three
different shear connection types. The employed shear connectors in the study were; size 14 (6mm diameter) self-drilling screw,
M12 coach screw, and M12 nut and bolt. The effective bending stiffness of composite cold-formed steel and plywood T-beam
assembly is calculated based on the slip modulus values computed from push-out tests. The effective bending stiffness was
increased by 25.5%, 18% and 30.2% for self-drilling screw, coach screw, nut and bolt, respectively, over the stiffness of coldformed steel joist alone. This finding suggests the potential to enhance the structural performance of composite cold-formed steel
and timber flooring system by mobilisation of composite action present between timber sheathing and CFS joist.
Key Words
cold-formed steel joists; structural plywood; material tests; push-out tests; load-slip behaviour; slip modulus
Address
Dheeraj Karki, Harry Far and Suleiman Al-hunity:School of Civil and Environmental Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney (UTS),
Building 11, Level 11, Broadway, Ultimo, NSW 2007, Australia