Abstract
A new type of precast steel reinforced concrete (PSRC) column was put forward in this paper. In order to study the
static performance of PSRC column and hollow precast steel reinforced concrete (HPSRC) column subjected to combined
compression and shear loading, a parametric test was carried out and effects of axial compression ratio, concrete strength and
shear ratio on the mechanical behavior of composite PSRC column and HPSRC column were explored. In addition, the cracks
development, load-span displacement relationship, strain distribution and shear bearing strength of column specimens were
emphatically focused. Test results implied that shear failure of all specimens occurred during the test, and higher strength of castin-place concrete, smaller shear ratio and larger axial compression ratio could lead to greater shear resistance, but when the axial
compression ratio was larger than 0.36, the shear capacity began to decrease gradually. Furthermore, truss-arch model for
determining the shear strength of PSRC column and HPSRC column was proposed and the calculated results obtained from
proposed method were verified to be valid.
Key Words
compression and shear test; mechanical behavior; precast SRC column; shear capacity
Address
Yang Chen: 1) Department of Civil Engineering, Shanghai University, Shanghai, 200444, China
2) State Key Laboratory of Green Building in Western China, Xi