Abstract
This paper researches a lightweight composite structure referred to as the Profiled Steel Sheeting Dry Board
(PSSDB). It is fundamentally produced by connecting a Profiled Steel Sheeting to Dry Board using mechanical screws. It is
mainly employed as floor panels. However, almost all studies have focused on researching the one-way structural performance.
Therefore, this study focuses on the bending behaviour of the two-way PSSDB floor system using both of Finite Element (FE)
and Experimental analysis. Four panels were used in the experimental tests, and a mild steel plate has been applied at the bottom
for two panels. For the FE process, models were created using ABAQUS software. 4 parametric studies have been utilized to
understand the system's influential elements. From the experimental tests, it was found that using Steel Plate shall optimize the
two-way action of the system and depending on the type of dry board the improvement in stiffness may reach up to 38%. It was
shown from the FE analysis that the dry board, profiled steel sheeting and steel plat can affect the system by up to 10 %, 17%
and 3% respectively, while applying a uniform load demonstrate a better two-way action.
Key Words
dry board; floor; profiled steel sheeting; two-way
Address
Marwan S. Al-Shaikhli:Building and Construction Technology Engineering Department, Madenat Alelem University College, Baghdad, Iraq
Wan Hamidon Wan Badaruzzaman:Director of PRASARANA, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia
Ahmed W. Al Zand:Department of Civil Engineering, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia