Abstract

In this paper the results of an experimental program devoted to the assessment of the cyclicrnbehaviour of full scale, European type, beam-column subassemblages with welded connections are presented.rnSix tests (five cyclic and one monotonic) have been carried out on three different series of specimens,rnencompassing a total of eighteen tests. The three specimen series have been designed with the aim of definingrnthe effect of the column size on the connection behaviour, under different applied loading histories. The testsrnhave evidenced the effect of the column size and panel zone design and of the applied loading history on therncyclic behaviour and failure modes of the connections.

Key Words

welded connections; cyclic tests; loading histories; rotation capacity; panel zone;failure modes.

Address

Elena Mele, Dipartimento di Analisi e Progettazione Strutturale (DAPS), Universita di Napoli \"Federico II\", P.le Tecchio 80, 80125 Napoli, ItalyrnLuis Calado, Departamento de Engenharia Civil (DECivil), Instituto Superior Tecnico, Av. Rovisco Pais,1049-001 Lisboa, PortugalrnAntonello De Luca, Dipartimento di Analisi e Progettazione Strutturale (DAPS), Universita di Napoli \"Federico II\", P.le Tecchio 80, 80125 Napoli, Italy